Yokogawa YTA50/70 Two Wire Head Mount Temperature Transmitter

The YTA70 delivers all the benefits found in the YTA50 while adding HART® digital protocol communication. The HART® protocol allows you to conveniently configue the transmitter using the latest FDT/DTM technology. The YTA70 is the choice for all your control applications.

Product Details

Yokogawa YTA50/70 Two Wire Head Mount Temperature Transmitter

YOKOGAWA YTA70 Temperature Transmitter


The YTA70 is a head mount type of temperature transmitter that accepts thermocouple, RTD , ohms or

DC milivolts input and converts it to a 4 to 20 mA DC signal for transmission. The YTA70 conforms to the standard DIN formB head mounting. The YTA70 supports HART  ® communication protocol.


Accuracy


Power Supply Effects : ± 0.005% of FS per Volt

RFI Effects

Tested per EN 50 082-2, field intensity up to 10 V/m.

EMC Conformity

EN61326

Input Type, Span and Range

Selection from thermocouples (T/C), 2-, 3-, and 4-

wire RTDs, ohms and DC milivolts. See Table 1 on

page 2.

Maximum Zero offset

±50% of selected maximum value

Input Resistance (for thermocouples, mV)

10 M?, or 3 k? at power-off

Input Lead Wire Resistance (for RTD, ohm)

5 ? per wire or lower

Sensor Burnout

High or Low

Output

Two wire 4 to 20 mA DC



YTA70.jpg

Xi'an XK is one of the professional suppliers of the yokogawa yta50/70 two wire head mount temperature transmitter. Offering you the best discount and original sources, we have many types of products for you. Coming in low cost, high quality, cheap price and good measurement performance, we welcome you to buy the product with our agent.

Specifications: Temperature Transmitters YTA50/YTA70

Accuracy (typical)

YTA50: ±0.1% of span or ±0.2deg C(0.36deg F) 
YTA70: ±0.1% of span or ±0.1deg C(0.18deg F)

Cold junction Compensation accuracy

(For T/C only) 
±1 deg C (1.8 deg F)

Power supply effect

±0.005% of FS per volt

Ambient temperature effect

YTA50: (±0.1% or ±0.1deg C) / 10 deg C 
YTA70: (±0.05% or ±0.05deg C) / 10 deg C

Input signal

Single input 
Input type is selectable: thermocouples, 2-, 3-, and 4-wire RTDs, ohm and DC milivolt

Output

Two wire 4 to 20 mA DC

Supply voltage

7 to 35 V DC
(7 to 28 V DC for Intrinsically safe type)

Ambient temperature

Option code may affect limits
-40 to 85 deg C (-40 to 185 deg F)

Mounting

DIN form B head mounting

Weight

50g (0.11lb)

Certificates

CENELEC or FM

 

Inquiry