SMV800 SmartLine Multivariable Transmitter of mass and volume flow measurements for liquids, gases, and superheated and saturated steam.Provide high precision measurement variables, compensation flow and integral data.
SMV800 SmartLine Multivariable Transmitter Combine differential pressure, static pressure and temperature sensor technology with the latest microprocessor technology to provide high precision measurement variables, compensated flow and integral data through a variety of communication protocols.Having a fault diagnosis function that is digitally accessible helps to give early warning of possible faults, minimize unplanned shutdowns, and reduce overall operating costs.
Analog Output Digital Communications:
Two-wire, 4 to 20 mA (HART & DE Transmitters only) Honeywell DE, HART 7 and Modbus protocol Modbus Model: RS-485 Half duplex communication interface. All transmitters, irrespective of protocol have polarity insensitive connection.
Materials Specifications:
Barrier Diaphragms Material:316L SS, Hastelloy® C-2762, Monel® 400 3, Tantalum, Gold-plated 316L SS, Goldplated Hastelloy® C-276, Gold-plated Monel® 400
Process Head Material:316 SS4, Carbon Steel (Zinc-plated)5, Hastelloy C-2766, Monel 400 7
Vent/Drain Valves & Plugs 1:316 SS4, Hastelloy C-2762, Monel 400 7
Meter Body Bolting:Carbon Steel (Zinc plated) standard. Options include 316 SS, NACE A286 SS bolts, Monel K500, Super Duplex and B7M.
Optional Adapter Flange and Bolts:Adapter Flange materials include 316 SS, Hastelloy C-276 and Monel 400. Bolt material for flanges is dependent on process head bolts material chosen. Standard adaptor o-ring material is glass-filled PTFE. Viton and graphite are optional.
Mounting Bracket:Carbon Steel (Zinc-plated) , 304 Stainless Steel or 316 Stainless Steel
Fill Fluid:Silicone Oil DC200, Silicone Oil 704, NEOBEE® M-20 or CTFE (Chlorotrifluoroethylene).
Electronic Housing:Pure Polyester Powder Coated Low Copper (<0.4%)-Aluminum. Meets Type 4X, IP66, & IP67. All stainless-steel housing is optional.
Process Connections : ¼”- NPT or ½”- NPT with adapter (meets DIN requirements)
Wiring:Accepts up to 16 AWG (1.5 mm diameter). For RS-485 connection, 24 AWG shielded twisted pair cable with nominal characteristic impedance of 120 ohm is recommended.
Net Weight : 8.3 pounds (3.8 Kg). With Aluminum Housing
Performance Under Rated Conditions – All Models:
Analog Output Digital Communications:Two-wire, 4 to 20 mA (HART & DE Transmitters only) Honeywell DE, HART 7 and Modbus protocol Modbus Model: RS-485 Half duplex communication interface. All transmitters, irrespective of protocol have polarity insensitive connection.